The CAD Pipe Layout drawing supplied with each project shows all the essential information needed for correctly installing the underfloor pipe work. It also shows information needed for commissioning and fitting the electrical controls. The pipe installer and electrician for the project will both require a copy.
Please ensure that the information shown on the drawing for your project matches site conditions. Any deviation to pipe layout should always be checked with your supplier.
The positioning of permanent fixtures (kitchen units, baths, toilets etc.) must be decided prior to any floor heating pipe being installed.
The roomstat positions shown on the CAD drawing are purely to show which room/area has a stat or other piece of control. Final positioning of stats should be done using manufacturers instructions/recommendations.
Keep pipe work 100mm in from all partitions, perimeter walls and permanent fixtures.